(1) Apply Nippeco SEP-3A grease to the following:
Entire Gear [21], particularly its teeth
Both sides of Washer (A) [25]
Both sides of Orbital Cam [24]
Both sides of Balance Weight [23]
Periphery of Connecting Piece (A) [19]
Tooth plane of Armature [31]
Contacting parts of Spindle [26] and Steel Ball D3.97 [62]
Entire Plunger [15]
Sliding part of Roller Holder [46] and Needle Roller [47]
(2) Apply Molub-Alloy No.777-1 grease to the following:
Inner diameter part of the gear assembly (metal part, grease stopper groove, and needle bearing part: 1.0 g)
Inner periphery of Connecting Piece (A) [19] (0.5 g)
Tapping Screw (W/Flange) D4 [38][49][57] ---------------------------- 1.96 ± 0.49 N
m (20 ± 5 kgfcm)
Machine Screw (W/Washer) M4 X 8 (Black) [65] --------------------- 1.96 ± 0.49 N
m (20 ± 5 kgfcm)
Machine Screw M4 X 30 (Black) [40] ------------------------------------ 1.96 ± 0.49 N
m (20 ± 5 kgfcm)
Seal Lock Hex. Socket HD. Bolt M3 [1][12] ---------------------------- 2.45 ± 0.49 N
m (25 ± 5 kgfcm)
Hex. Socket HD. Bolt M5 X 16 [69]--------------------------------------- 3.43 to 6.37 N
m (35 to 65 kgfcm)
Special Bolt M4 [5]------------------------------------------------------------4.4 ± 1.0 N
m (45 ± 10 kgfcm)
Machine Screw (W/Washer) M3.5 X 6 [42]----------------------------- 0.6 ± 0.15 N
m (6 ± 1.5 kgfcm)
Check the following after reassembly:
(1) Confirm normal switching operation of Switch (E) (1p Screw Type) W/Lock [41].
(2) Confirm that the stroke speed changes depending on the turning amount of Controller [43].
(3) Confirm that the blade can be attached securely.
Upon completing disassembly and repair, measure the insulation resistance and conduct an insulation test
(dielectric strength test).
Insulation resistance: 7 M or more with 500 V DC megohm tester.
Dielectric strength: AC 4,000 V for 1 minute, with no abnormalities ---- 110 V, 220 V, 230 V, 240 V
AC 2,500 V for 1 minute, with no abnormalities ---- 120 V
After no-load operation for 30 minutes, the no-load current value should be as specified below at a
frequency of 50/60 Hz.
Voltage (V) 110 120 220 230 240
Current (A) Max. 4.0 3.0 1.8 1.8 1.8
Screw Tightening Torque
Checking after Reassembly
Application of Lubricant
Insulation Test
No-load Current